Split Type Wall-mounted Inverter Room Air ConditionerInstruction Manual Thank you for purchasing a Shinco air conditioner.Toguarantee safety and b
9To cancel time setting press the TIMER button. Nothing will be displayedon the LCD screen.One hour setting Press the 1HR button, the one hour setting
10Attention:1. Select the cooling, heating or dehumidify mode according to the roomtemperature.2. If the quantity of clothes to dry is too large or th
11In heating mode: one hour after activating the SLEEP mode the preset temperatureincreases by 2 degrees automatically, and two hours after the prese
12Clean the air filter (once every two weeks)1. Hold the two ends of the grill and gently push the filters downward2. Use vacuum cleaner or w
136. Trouble ShootingBefore calling a repair man, please check the followings:The air conditionerdoes not workThe unit does notblow warm air inheating
14To guarantee the unit it must be installed according to the instructions in this manual.• The air conditioner has to be grounded properly.• Check th
15 • The unit has to be more than 1 metre away from a fluorescent lamp or other electric bulbs ( they could interfere with the remote
162-2 Drill a hole in the wall• Select the location.• Drill a hole of approximately 6.5 cm diameter Insert the wall-through sheath into th
17The drain hose must be put below the copper pipe. Put to-gether the refrigerant pipe, drain hose and the connecting wireof indoor and outdoor units.
18The outdoor unit should be installed on a solid base. (Such as concrete) If it is in-stalled against a brick wall, the thickness of the brick wall s
To Consumers1. This air conditioning unit should be installed and repaired by a qualified technician.2. The air conditioning unit must be grounded rel
191. pipe cutting Use pipe cutter to cut the copperpipe correctlyqualifiedCopper pipe 90UnqualifiedBurrtilted ruggedCopper pipePipe cutter2.remove
203-4 Electric wire connectionL3 L4 S GIndoor Electric partsAir-break switchL3 L4 S GOutdoor Electric pa
214. Test RunMake sure all the pipe joints have been screwed tightly, then clean the pipes and verifythe vacuum.Remove the valve core copper caps of t
224-3 Instructions to ConsumersRemarkCheck the following items according to the related contents of this manual.Indoor unit :Is the noise abnormal?Do
23The above mentioned cooling and heating capacities are standard andmay vary slightly in accordance with the ambient temperature.Please use the unit
Serial No.: eb45493Version:090318
SAFETY PRECAUTIONSPlease read the SAFETY AND OPERATING INSTRUCTIONS carefully before operating theunit.Please respect the following safety precautions
OPERATION PRECAUTIONS WARNING CAUTIONDo not operate with wet hands.Avoid staying directly in front of operating unit.Do not insert foreign objects
CONTENTS4To Consumers ... 1SAFETY PRECAUTIONS ... 2OPERATI
6
7Two AAA Size 1.5v batteriesRemove front cover(Change the batteries)4. Wind speed display : (Low) (Medium) (High) (Auto)5. Present time displ
83-2 Wind Speed-Wind Direction AdjustmentSET TIMERTIMEAttention:The clock can be set even if the unit is closed.For your comfort, adjust the wind spee