Split Type Wall-mounted Inverter Room Air Conditioner
Instruction Manual
Thank you for purchasing a Shinco air conditioner.To
guarantee safety and best efficiency, please read this manual
carefully and keep it for future reference.
Applicable to
KFR-25GWZ/BM
KFR-35GWZ/BM
KFR-50GWZ/BM
KFR-70GWZ/BM
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1 - Instruction Manual

Split Type Wall-mounted Inverter Room Air ConditionerInstruction Manual Thank you for purchasing a Shinco air conditioner.Toguarantee safety and b

Page 2 - To Consumers

9To cancel time setting press the TIMER button. Nothing will be displayedon the LCD screen.One hour setting Press the 1HR button, the one hour setting

Page 3 - SAFETY PRECAUTIONS

10Attention:1. Select the cooling, heating or dehumidify mode according to the roomtemperature.2. If the quantity of clothes to dry is too large or th

Page 4 - OPERATION PRECAUTIONS

11In heating mode: one hour after activating the SLEEP mode the preset temperatureincreases by 2 degrees automatically, and two hours after the prese

Page 5 - CONTENTS

12Clean the air filter (once every two weeks)1. Hold the two ends of the grill and gently push the filters downward2. Use vacuum cleaner or w

Page 6

136. Trouble ShootingBefore calling a repair man, please check the followings:The air conditionerdoes not workThe unit does notblow warm air inheating

Page 7

14To guarantee the unit it must be installed according to the instructions in this manual.• The air conditioner has to be grounded properly.• Check th

Page 8 - 3-1 Setting the clock

15 • The unit has to be more than 1 metre away from a fluorescent lamp or other electric bulbs ( they could interfere with the remote

Page 9 - 3-3 Timer setting

162-2 Drill a hole in the wall• Select the location.• Drill a hole of approximately 6.5 cm diameter Insert the wall-through sheath into th

Page 10 - 3-6 Drying clothes mode

17The drain hose must be put below the copper pipe. Put to-gether the refrigerant pipe, drain hose and the connecting wireof indoor and outdoor units.

Page 11 - 3-9 Sleeping mode

18The outdoor unit should be installed on a solid base. (Such as concrete) If it is in-stalled against a brick wall, the thickness of the brick wall s

Page 12 - 4. Maintenance

To Consumers1. This air conditioning unit should be installed and repaired by a qualified technician.2. The air conditioning unit must be grounded rel

Page 13 - Raise and

191. pipe cutting Use pipe cutter to cut the copperpipe correctlyqualifiedCopper pipe 90UnqualifiedBurrtilted ruggedCopper pipePipe cutter2.remove

Page 14 - 6. Trouble Shooting

203-4 Electric wire connectionL3 L4 S GIndoor Electric partsAir-break switchL3 L4 S GOutdoor Electric pa

Page 15 - Installation Instruction

214. Test RunMake sure all the pipe joints have been screwed tightly, then clean the pipes and verifythe vacuum.Remove the valve core copper caps of t

Page 16 - 2-1Fix the wall-mounted plate

224-3 Instructions to ConsumersRemarkCheck the following items according to the related contents of this manual.Indoor unit :Is the noise abnormal?Do

Page 17 - Indoor unit

23The above mentioned cooling and heating capacities are standard andmay vary slightly in accordance with the ambient temperature.Please use the unit

Page 18 - 2-5 Arrangement of Pipes

Serial No.: eb45493Version:090318

Page 19 - Outdoor unit

SAFETY PRECAUTIONSPlease read the SAFETY AND OPERATING INSTRUCTIONS carefully before operating theunit.Please respect the following safety precautions

Page 20 - 3-3 Drain Hose

OPERATION PRECAUTIONS WARNING CAUTIONDo not operate with wet hands.Avoid staying directly in front of operating unit.Do not insert foreign objects

Page 21 - 3-4 Electric wire connection

CONTENTS4To Consumers ... 1SAFETY PRECAUTIONS ... 2OPERATI

Page 24 - Main Specifications

7Two AAA Size 1.5v batteriesRemove front cover(Change the batteries)4. Wind speed display : (Low) (Medium) (High) (Auto)5. Present time displ

Page 25 - Version:090318

83-2 Wind Speed-Wind Direction AdjustmentSET TIMERTIMEAttention:The clock can be set even if the unit is closed.For your comfort, adjust the wind spee